Gas Logs in Placentia, Fitted to a Sound Flue

Were You Quoted for This?

Where We Start

A log set is a gas appliance, and the quote should say how the line, the valve and the venting will be handled. We measure the opening, go over vented and vent-free options and their limits in your room, and pick a burner that suits the space. The gas line comes in with a valve you can reach, vented sets get the damper held partly open as required, and we light the set with you.

Opening measured before any set is shown
Vented and vent-free sets compared for the room
Gas line run with a reachable valve
Damper set partly open on vented logs
Flame and draft watched at the first lighting

Vented or Vent-Free, Told Straight

Gas log sets come in two families, and the choice between them is often sold rather than explained. A vented set burns with an open damper and sends everything up the chimney, which gives a tall, lively flame and leaves the room air alone, but puts out modest heat. A vent-free set burns cleaner and keeps more of its heat in the room, but what it burns stays in the house too, along with the water vapour every gas flame makes. Vent-free sets have rules about room size and must carry an oxygen sensor, and some owners notice an odour or moisture on windows. Neither is wrong. What matters is which one matches how you use the fireplace, and that answer should come from the room and your habits, not from whichever set is in the van.

If you are holding a quote for a vent-free set because it is "more efficient", ask how big the room is and whether anyone in the house has breathing trouble. If you are holding a quote for a vented set, ask whether anyone has looked at the flue. A vented set relies on the chimney to carry its exhaust, so a cracked tile, a nest or a blocked cap matters as much as it would with wood. We check the flue and damper before fitting any vented set, and fix the damper so it cannot close fully while the burner is on. For owners who light a fire mostly for the look, a vented set usually suits well once the chimney is confirmed sound. A vented set also leaves the room air as it was, which matters in a small or tightly sealed room.

Sizing, Fitting and the Price

A set that looks right is one sized to the firebox, with logs that fill it without crowding the opening. We take the dimensions of your firebox before suggesting sets, since a burner pan that is too wide pushes flame onto the face and one too narrow looks lost. The gas line also matters. Plenty of older fireplaces have a log lighter pipe and a key valve already, but the pipe may be too small for a full set, or the valve may be worn. We check the line and tell you whether it can be used as it is or needs to be replaced up to the firebox. If the firebox is a factory-built metal unit, only sets the maker approves for that model can go in it, and we check the plate before any set is suggested. That rules some sets out before you fall for them.

Gas log sets carry no single published price, because the set itself is the largest part of the cost and you choose it. Once you have picked a set, our written quote lists the set, the burner, the gas work and any damper or flue work as separate lines. If a set is already installed and someone has told you it needs replacing, we check the burner, the logs and the pilot before agreeing; a set that only needs cleaning and the logs placed back in their proper positions is a much smaller job. The fitting visit ends with the set lit, the flame checked with you watching, and the controls shown. Nothing is added to the job without your say. Ceramic fibre and cast cement logs differ in weight, detail and price, and we explain both.

How Shipley Chimney Sweep Handles It

Photo First

Each finding comes with a picture taken on the day

Sorted by Urgency

Now, later or no action, item by item

Price in Writing

Every repair line priced before you approve it

Your Report

Share it with anyone, hire anyone

Other Work We Check and Price

Chimney Sweep

Flue brushed and vacuumed, then photographed bare, so you can tell whether a quoted repair is real damage or only soot.

Open the page

Chimney Inspection

A visual check of the reachable chimney, written up with photos and each finding sorted into now, later or no action.

Open the page

Chimney Repair

Repairs scoped from our own photos, split into what must happen before the next fire and what can wait a season.

Open the page

Fireplace Inspection

The room side of the fireplace examined, from firebrick and damper to hearth and trim gaps, with photos of every concern.

Open the page

Fireplace Repair

Cracked firebrick, loose panels, failed dampers and split hearths repaired after we show you why each one needs doing.

Open the page

Chimney Level 2 Inspection

Recorded camera pass through the flue plus the hidden parts reachable from inside the house; the visit most second opinions call for.

Open the page

Chimney Cap Installation

A cap fitted when the photos show rain, birds or loose embers getting in, sized to one flue tile or the whole crown.

Open the page

Chimney Flashing Repair

Roofline metal checked and photographed, then patched or replaced only where water is really getting past it.

Open the page

Chimney Masonry Repair

Brick and joint work sized to what the photos show, from a few flaking faces to a full repoint.

Open the page

Chimney Rebuilds

A rebuild suggested only when photos show loose courses or a lean; otherwise we say which smaller repair will do.

Open the page

Fireplace Cleaning

Firebox, smoke shelf and glass doors cleaned so the inside can be judged without a layer of soot in the way.

Open the page

Gas Fireplace Cleaning

Gas set taken apart, burner and pilot cleared, glass cleaned and the flame watched, so a service note on a report can be closed.

Open the page

Gas Fireplace Repair

Pilot, igniter, valve and remote faults found with a meter, so you pay only for the part that has really failed.

Open the page

Fireplace Remodel

Surround, hearth and opening reworked after the firebox and flue behind them have been confirmed sound.

Open the page

Fireplace Inserts

Sealed wood or gas inserts fitted with a full-height liner, after a camera confirms the flue can take one.

Open the page

Pellet Stove Repair

A stalled pellet stove tested one stage at a time, from the fuel path to the circuit board, with results shown before repairs.

Open the page

Wood Stove Repair

Leaky door seals, cracked glass, broken firebrick and tired baffles replaced so the stove holds its air settings again.

Open the page

Chimney Seismic Retrofit

Brick chimneys looked at for quake risk, with bracing, strapping or a partial rebuild offered only when the photos support it.

Open the page

Chimney Crown Repair

Crown cracks photographed up close, then coated if shallow or replaced if water is already working beneath them.

Open the page

Dryer Vent Cleaning

Lint cleared from the full duct run, with airflow measured before and after so you can see what changed.

Open the page

Chimney Liner Installation

A new liner offered only when the camera shows the old flue cannot be trusted, with the footage shared before you decide.

Open the page

Chimney Leak Repair

Water traced to the part really letting it in, so the repair targets the source instead of every possible suspect.

Open the page

Chimney Waterproofing

Water repellent applied after repairs, never in place of them, with the brick's condition photographed first.

Open the page

Chimney Damper Repair

A sticking or broken damper worked, photographed and either repaired in place or replaced with a top-mounted seal.

Open the page

Chimney Chase Cover

Rust and standing water on top of a framed chimney photographed, with a made-to-measure cover fitted when the old one has failed.

Open the page
Call (657) 233-4596