Fireplace Remodel Plans in Placentia, Checked First

Were You Quoted for This?

Where We Start

Remodel bids sometimes skip the question of whether the chimney behind the new face can carry it. We answer that first with an inspection, then plan the surround, hearth and mantel with the code gaps to combustible trim built in. Tile, stone, plaster and wood finishes are all possible. If the existing face can stay with a few repairs, we tell you that too, because a full remodel is not always the fix you need.

Chimney condition confirmed before design
Trim and hearth gaps set to code in the plan
Tile, stone, plaster or wood finishes
Repair-only option shown when the face can stay
Written scope approved before ordering

What a Designer's Drawing Leaves Out

Remodel plans for a fireplace are usually drawn from the room: the stone or tile, the mantel height, the line of the shelf against the ceiling. What a drawing rarely shows is the state of the firebox, the damper and the flue behind the new face, or whether the planned trim and shelf sit far enough from the opening for the fire you intend to burn. We look at the plan and the fireplace together. If the firebox has open joints or a cracked back wall, that is fixed before any facing goes on, because tearing out new stone to reach it later doubles the bill. If the damper is seized or rusted, it is cheaper to deal with now. And if the new mantel or a wood surround would sit too close to the fire, we tell you before the material is ordered.

Owners also come to us with a contractor's remodel quote and a feeling that something is missing. Often it is one of three things: no line for the firebox or chimney at all, a clearance problem nobody has measured, or a plan to keep burning wood in a fireplace that should first have a liner. Each of those is easy to fix on paper and expensive to fix in plaster. Our written scope for a remodel puts the hidden work first, the visible work second, and gives each stage its own price, so you can see what is structural and what is finish. Where the existing fireplace is in good order, the scope says so in a line and moves straight to the design you came for. That keeps the budget honest from the first day.

Changing Fuel as Part of the Remodel

Many Placentia and Fullerton remodels include a change of fuel: a wood fireplace turned into a gas log set, a gas insert, or a sealed unit with a clean modern face. Each of those changes what the chimney has to do, and the NFPA 211 standard treats a change of fuel or appliance as a reason for a Level 2 inspection before the work. That inspection costs $375 and is worth doing before the design is fixed, because the camera can show whether the flue will need a liner, which affects both the budget and the depth of the new firebox. Planning a gas insert into the existing firebox carries a published range of $2,700 to $5,400; a vented gas fireplace built where no fireplace stood before falls in the $4,300 to $8,600 range.

South Coast AQMD rules also shape the choice. Winter no-burn alerts under Rule 445 limit wood fires on bad air days, and owners who light a fire mainly for the look often find that gas suits the way they actually use the room. We do not push the change; a wood fireplace in sound order is a fine thing to keep. What we do is lay out the options with their real costs and the work each would need behind the face, so the remodel is decided with the full picture. The finished fireplace should look the way you want and work safely, and the written scope shows how both parts are covered, line by line. If you plan to keep burning wood, the remodel is also the right time to settle the flue question, since a liner is far easier to fit before new stone surrounds the opening.

How Shipley Chimney Sweep Handles It

Photo First

Each finding comes with a picture taken on the day

Sorted by Urgency

Now, later or no action, item by item

Price in Writing

Every repair line priced before you approve it

Your Report

Share it with anyone, hire anyone

Other Work We Check and Price

Chimney Sweep

Flue brushed and vacuumed, then photographed bare, so you can tell whether a quoted repair is real damage or only soot.

Open the page

Chimney Inspection

A visual check of the reachable chimney, written up with photos and each finding sorted into now, later or no action.

Open the page

Chimney Repair

Repairs scoped from our own photos, split into what must happen before the next fire and what can wait a season.

Open the page

Fireplace Inspection

The room side of the fireplace examined, from firebrick and damper to hearth and trim gaps, with photos of every concern.

Open the page

Fireplace Repair

Cracked firebrick, loose panels, failed dampers and split hearths repaired after we show you why each one needs doing.

Open the page

Chimney Level 2 Inspection

Recorded camera pass through the flue plus the hidden parts reachable from inside the house; the visit most second opinions call for.

Open the page

Chimney Cap Installation

A cap fitted when the photos show rain, birds or loose embers getting in, sized to one flue tile or the whole crown.

Open the page

Chimney Flashing Repair

Roofline metal checked and photographed, then patched or replaced only where water is really getting past it.

Open the page

Chimney Masonry Repair

Brick and joint work sized to what the photos show, from a few flaking faces to a full repoint.

Open the page

Chimney Rebuilds

A rebuild suggested only when photos show loose courses or a lean; otherwise we say which smaller repair will do.

Open the page

Fireplace Cleaning

Firebox, smoke shelf and glass doors cleaned so the inside can be judged without a layer of soot in the way.

Open the page

Gas Fireplace Cleaning

Gas set taken apart, burner and pilot cleared, glass cleaned and the flame watched, so a service note on a report can be closed.

Open the page

Gas Fireplace Repair

Pilot, igniter, valve and remote faults found with a meter, so you pay only for the part that has really failed.

Open the page

Fireplace Inserts

Sealed wood or gas inserts fitted with a full-height liner, after a camera confirms the flue can take one.

Open the page

Pellet Stove Repair

A stalled pellet stove tested one stage at a time, from the fuel path to the circuit board, with results shown before repairs.

Open the page

Wood Stove Repair

Leaky door seals, cracked glass, broken firebrick and tired baffles replaced so the stove holds its air settings again.

Open the page

Gas Logs

Gas log sets chosen for your opening and fuel type, with the line, valve and damper setup confirmed at a test fire.

Open the page

Chimney Seismic Retrofit

Brick chimneys looked at for quake risk, with bracing, strapping or a partial rebuild offered only when the photos support it.

Open the page

Chimney Crown Repair

Crown cracks photographed up close, then coated if shallow or replaced if water is already working beneath them.

Open the page

Dryer Vent Cleaning

Lint cleared from the full duct run, with airflow measured before and after so you can see what changed.

Open the page

Chimney Liner Installation

A new liner offered only when the camera shows the old flue cannot be trusted, with the footage shared before you decide.

Open the page

Chimney Leak Repair

Water traced to the part really letting it in, so the repair targets the source instead of every possible suspect.

Open the page

Chimney Waterproofing

Water repellent applied after repairs, never in place of them, with the brick's condition photographed first.

Open the page

Chimney Damper Repair

A sticking or broken damper worked, photographed and either repaired in place or replaced with a top-mounted seal.

Open the page

Chimney Chase Cover

Rust and standing water on top of a framed chimney photographed, with a made-to-measure cover fitted when the old one has failed.

Open the page
Call (657) 233-4596